The TP 1079 Front Tap Shoe is designed for use with the 299 AT&T Lucent 307 (Cosmic with Protection plugs into heat coils) type Central Office Main Frame Connector Blocks.

DESCRIPTION

The TP 1079 consists of the following components:

  • Injection molded plastic contact pin housing (black)
  • 200 plated, field replaceable Tip-Ring contact pins
  • 200 contact pin springs made of .010 MW, S&B
  • Equipped with two screw-down latching devices for precision fit
  • A 15 foot, 100 pair, 28 AWG stranded (7/38) tinned wire cable; soldered terminations
  • Cable strain relief complete with snap hook for secure positioning
  • Four 25 pair Female Cinch Jones


Division Line
Lucent 310/311
Lucent 310/311

Lucent 310/311
Lucent 310/311

Lucent 310/311
Lucent 310/311

TP 1002
TP 1002

The TP 1002 Front Tap Shoe is designed for use with the AT&T/Lucent 310/311 Central Office Main Frame Connectors.

The TP 1002 (100 pair) is used to connect the user's test equipment to the central office terminal test field.

DESCRIPTION
The TP 1002 consists of the following components:

  • Plastic contact pin housing (black).
  • 200 gold plated, field replaceable, Tip Ring contact pins.
  • Two 15 foot, 50 pair 28 gauge stranded (7/38) tinned wire cable. soldered terminations.
  • Cable strain relief provided at both ends.
  • Four 25 pair Female Cinch Jones connectors.
  • Equipped with two mounting latching screws.


Division Line
Lucent 308
Lucent 308

Lucent 308
Lucent 308

TP 1004 Wiring Map
TP 1004 Wiring Map

TP 1004
TP 1004

The TP 1004 is designed for use with the Lucent 305 block.

DESCRIPTION
The TP 1004 consists of the following components:

  • Two 15 foot, 50 pair 28 gauge stranded (7/38) tinned wire cable. Solder terminations.
  • Four 25 pair female Cinch Jones connectors.


Division Line
Lucent 308
Lucent 308

Lucent 308
Lucent 308

TP 1005 Wiring Map
TP 1005 Wiring Map

TP 1005
TP 1005

The TP 1005 Front Tap Shoe is designed for use with the Lucent 308 block.

DESCRIPTION:

The TP 1005 consists of the following components:

  • Plastic contact pin housing (black).
  • 200 gold plated, field replaceable, Tip Ring contact pins.
  • Two 15 foot, 50 pair 28 gauge stranded (7/38) tinned wire cable. soldered terminations.
  • Cable strain relief provided at both ends.
  • Four 25 pair Female Cinch Jones connectors.


Division Line
TP 1005A
TP 1005A

TP 1005A
TP 1005A

TP 1005A
TP 1005A

TP 1005A
TP 1005A

Lucent 308 Block
Lucent 308 Block

The TP 1005A Front Tap Shoe is designed for use with the Lucent 308 block. (The 1005A has 4 male amp connectors in place of cinch jones connectors).

DESCRIPTION

The TP 1005A consists of the following components:

  • Plastic contact pin housing (black).
  • 200 gold plated, field replaceable, Tip Ring contact pins.
  • Two 15 foot, 50 pair 28 gauge stranded (7/38) tinned wire cable. soldered terminations.
  • Cable strain relief provided at both ends.
  • Four Amphenol Male Metal Cover Amps.


Division Line
 
88/108 Block

AT&T 88/108

TP 1013 and Block Top View


TP 1013 Close


TP 1013 and Cover


The TP1013 Front Tap Shoe is designed for use with the 88/108/110 Series Blocks . It is used to connect the user's test equipment to the central office terminal test field.

DESCRIPTION
The TP 1013 consists of the following components:

  • Machined, plastic contact pin housing.
  • 200 gold plated Tip Ring contact pins
  • One 15 foot, 50 pair, 28 gauge stranded (7/38) tinned wire cable, soldered terminations
  • Latching mechanism to assure proper connection and contact.
  • Two 25 pair Female Cinch Jones

Division Line

TP 1015H
TP 1015 larger view not available

TP 1015H
TP 1015 larger view not available

TP 1015H
TP 1015 larger view not available

The TP 1015H Front Tap Shoe is a specialized shoe and more expensive because it is meant for initial internal testing. This FTS is designed for use with the AT&T/HUB 76 terminal block. (If you are doing standard testing, see our TP1016 or TP1015 Front Tap Shoes)

DESCRIPTION:

The TP 1015H consists of the following components:

  • Plastic contact pin housing (black).
  • 200 gold plated, field replaceable, Tip Ring contact pins.
  • Two 15 foot, 50 pair 28 gauge stranded (7/38) tinned wire cable. soldered terminations.

Division Line

112 Block
112 Block

TP 1081
Full View
TP 1081

TP 1081
Probe View
TP 1081

The TP1081 Front Tap Shoe is designed for use with the Lucent/Avaya/Cosmic 112 Central Office Main Frame Connector Blocks (alternate latch allows this part to also work with the Lucent/Cosmic/Avaya 89F1F-100 Block).

DESCRIPTION:

The TP1081 Front Tap Shoe consists of the following components:

  • Injection molded plastic contact pin housing (black)
  • 200 plated Tip-Ring contact pins
  • Equipped with two screw-down latching devices for precision fit
  • 15 foot, 100 pair, 28 AWG stranded (7/38) tinned wire cable; soldered terminations
  • Cable strain relief complete with snap hook for secure positioning
  • Four 25 pair female Cinch Jones connectors

Please specify wiring direction (top to bottom, left to right, etc.)


Division Line

89F1F-100
Full View
Lucent 89F1F-100
TP 1081 attached to 89F1F-100
Lucent 89F1F-100

TP 1081 Full View
TP 1081 Larger view

TP 1081 Probes
TP 1081 larger view
 

The TP1081 Front Tap Shoe is designed for use with the (Lucent) 89F1F-100 Central Office Main Frame Connector Blocks (alternate latch allows this part to also work with the Lucent/Avaya/Cosmic 112)

DESCRIPTION:

The TP1081 Front Tap Shoe consists of the following components:

  • Injection molded plastic contact pin housing (black)
  • 200 plated Tip-Ring contact pins
  • Equipped with two screw-down latching devices for precision fit
  • 15 foot, 100 pair, 28 AWG stranded (7/38) tinned wire cable; soldered terminations
  • Cable strain relief complete with snap hook for secure positioning
  • Four 25 pair female Cinch Jones connectors

    Please specify wiring direction (top to bottom, left to right, etc.)

Installation Instructions:
tp1081installation89f1f-100.pdf (150 KB)

You will need Adobe Acrobat Reader to view these documents. Get Adobe Acrobat.

Division LineContact Us 

© 2000 Custom Assembly, Inc.
All rights reserved